Product Specifications
100-120 VAC, 60Hz
Less than 300 u amps earth leakage (tested per UL 2601)
1.6 amp Type T (time delay) 250V
2.9 m (9 feet) long with integrally molded hospital grade plug
5 hours operating time at 100 mL/hr (fully charged new batteries) 8 hours to recharge to 80% of capacity. Internal charge system recharges batteries whenever the device is connected to an AC outlet
Primary Infusion: 0.1 to 99.9 mL/hr in 0.1 mL/hr increments
1 to 1200 mL/hr in 1 mL/hr increments
Piggyback Infusion: 0.1. to 99.9 mL/hr in 0.1 mL/hr increments
1 to 500 mL/hr in 1 mL/hr increments
Note: Rate limits can be configured for values less Than those stated above.
0.1 – 99.9 mL in 0.1 mL increments 1- 9999 mL mL/hr in 1 mL increments
Note: Volume to be Infused limits can be configured for values less than those stated above
0.1 – 5 mL/hr in 0.1 mL increments (configurable option) or programmed rate whichever is less.
500 mL/hr (to be used only when not connected to patient)
At the same rate programmed for the current primary or piggyback infusion.
Measured accumulations of approximately
25 microliters
50 microliters
100 microliters 150 microliters
The Air Bubble Setting is a configurable option.
Allows the pump channel to automatically restart if an occlusion is relieved within one minute after detection. This configuration option allows 0 to 9 restarts before manual intervention is required.
Alarm sensitivity is a configurable option. Rate range in mL/hr
<21
2 psig (Minimum)
5 psig (Moderate)
9 psig (Maximum)
21- 200
4 psig (Minimum)
8 psig (Moderate)
12 psig (Maximum)
>200
6 psig (Minimum)
11 psig (Moderate)
15 psig (Maximum)
Approximately 10″ H x 7.75″ W x 7.75″ D
(254 x 197 x 197 mm)
Not including clamp knob or power cord
Approximately 10.4 lbs (4.7kg)
59º F – 100º F (15º C – 38º C)
-20º F – 135º F (-29ºC – 57º C), 10-100% Reliable Humidity including condensation, 500-1060 hPa Barometric Pressure
Less than 0.2 ohms (tested per UL-2601)
Pump will operate at all programmable flow rates with a solution container height ranging from -36 to +48 inches. Container height is measured from the pump channel selected for use.
Attachment to a remote nurse call system A variety of systems exist which enable alert and alarm conditions to be transmitted to a remote location via the communications port on the rear panel assembly of the pump. See the service manual for additional information.
Preset Label Library
User Defined Label Library
Dose Calculator
View Limits Soft Key
Programmable Personalities